Vapour Membrane

Features & Benefits
- Low emissivity reflective surface enhances thermal performance of the structure into which it is incorporated (still air cavity required)
- Air and vapour control layer
- Triple ply construction incorporating an adhesive strip located on the outer edge of the membrane and follows the dotted overlap line
- Provides an airtight system when installed with sealed laps
- Excellent air and vapour resistance
- Integrated tapes for quicker installation and reliable effective joint sealing
- Corrosion and damage resistant reflective surface
- Helps to avoid condensation risk in accordance with BS5250 requirements
- BM TRADA independently certified for all applications
- Class 1 surface spread of flame to BS 476-7
Specifications
Nail Tear Strength (N) to EN 12310-1 with mods | 160 along roll, 160 across roll |
Tensile Strength (N/50mm) to EN 12311-1 mods | 229 along roll, 226 across roll |
Water vapour resistance (MNs/g) to EN 1931 | >589 |
Thermal resistance m²K/W heat flow horizontal | 0.78 |
Weight g/m² | 150 |