15K Universal Tile Vent

Uses
- For tile roof ventilation, soil vent pipes or mechanical extract ventilation (with accessories)
- For remedial work on existing roofs
- Suitable for roof pitches between 17.5° and 60°
- For use at high level or low level where the roof construction does not allow eaves or ridge vents
Features & Benefits
- Universal design suits all single lap interlocking roof tiles.
- Low profile design.
- Choice of four colours
- Adaptor available for soil ventilation or mechanical extraction
- Efficient, unobtrusive and easy to install
- Complies with current Building Regulations; BS5250 & BS5534, ICP2
Installation
- Position the vent tile directly in line with tile below. Use tile vent to mark position of hole. Cut the felt diagonally in a cross shape and pin to back of rafters.
- Position the vent into the cut hole. All tile vents must be mechanically fixed down. Lay tile on both sides of the base one nailed down. Remove protective tape and dress around the tiles.
- Once tile vent is dressed to the tile, clip the cap onto the base securely. Carry on tiling up the roof.
Specifications
Code | IVTG5 |
Free Area | IVTG5—20,000mm² per vent |
Size | Universal |
Material | Manufactured from ABS & VO fire retardant material |
Colour | Terracotta, Brown, Grey, Red streak, Black, Blue/Black |
Airflow resistance when used as SVP (100mm pipe) | 54m³/hr 0.8Pa, 108m³/hr 2.6Pa, 216m³/hr 11.5Pa |
IVTG5 Airflow resistance with 150mm TT13 adaptor | 216m³/hr (60lt/sec) 19.5Pa |