20K Universal Tile Vent

20K Universal Tile Vent
Click to see full view

Uses

  • For tile roof ventilation, soil vent pipes or mechanical extract ventilation (with accessories)
  • For remedial work on existing roofs
  • Suitable for roof pitches between 17.5° and 60°
  • For use at high level or low level where the roof construction does not allow eaves or ridge vents

Features & Benefits

  • Universal design suits all single lap interlocking roof tiles.
  • Low profile design
  • Choice of two colours
  • Wind tunnel tested
  • Perfect solution for heat recovery systems with 150mm adaptor
  • Efficient, unobtrusive and easy to install
  • Complies with current Building Regulations; BS5250 & BS5534, ICP2

Installation

  1. Position the vent tile directly in line with tile below. Use tile vent to mark position of hole. Cut the felt diagonally in a cross shape and pin to back of rafters.
  2. Position the vent into the cut hole. All tile vents must be mechanically fixed down. Lay tile on both sides of the base one nailed down. Remove protective tape and dress around the tiles.
  3. Once tile vent is dressed to the tile, clip the cap onto the base securely. Carry on tiling up the roof.

Specifications

Code Brown (9854-20-0247), Slate Grey (9854-20-0429), 150mm adaptor (979700)
Free Area 20,000mm² per vent
Size Universal
Material Soft and Rigid UPVC
Airflow resistance when used as SVP (100mm pipe) 15 litres/sec 3 Pascals, 30 litres/sec 11 Pascals, 60 litres/sec 43 Pascals