Uniline Tile Vent

Uses
- For tile roof ventilation, soil vent pipes or mechanical extract ventilation (with accessories)
- For remedial work on existing roofs
- Suitable for roof pitches between 20° and 60°
- For use at low level where the roof construction does not allow eaves or ridge vents
- Not recommended at high level, due to lair pockets created by large air capacity and wide spacings
Features & Benefits
- Low profile cowl is the smallest available for the airflow capacity
- Colour matched with UV stable surface treatment
- Efficient, unobtrusive and easy to install
- Underlay opening protector supplied to maintain the function of the underlay
- Integral 4mm insect screen
- Complies with current Building Regulations; BS5250 & BS5534, ICP2
- Manufactured from ABS and VO fire retardant material for high quality finish and robust construction
Installation
- Select ventilator position between rafters. Mark opening and cut diagonally corner to corner and fold back. Make a slit above opening and slide Underlay protector
- On smaller tiles the batten may need to be cut to allow for the ventilator. Shorter lengths of batten may be fixed above or below the opening for additional support.
- Lay and fix tiles overlapping the tile vent on each side, using the clip on the right side of the vent to connect to the tile.
- Secure tile vent to batten by carefully nailing through hole provided. Continue tiling in the normal way.
Specifications
Free Area | IVTG5—20,000mm² per vent |
Size | To suit concrete/clay tile profile |
Material | Manufactured from ABS & VO fire retardant material |
Colour | To suit tile |
Code | ITG5 |
IVTG5 Airflow resistance when used as SVP (100mm pipe) | 54m³/hr (15 lt/sec) 0.8Pa, 108m³/hr (30lt/sec) 2.6Pa, 216m³/hr (60lt/sec) 11.5Pa |
Airflow resistance with 150mm TT13 | 216m³/hr (60lt/sec) 19.5Pa |