IVT G5 Universal Tile Vent

Uses
- For tile roof ventilation, soil vent pipes or mechanical extract ventilation (with accessories)
- For remedial work on existing roofs
- Suitable for roof pitches between 20° and 60°
- For use at high level or low level where the roof construction does not allow eaves or ridge vents
Features & Benefits
- Universal design suits all single lap interlocking roof tiles.
- Six colours with UV stable surface treatment
- Efficient, unobtrusive and easy to install
- Compressible foam filler ensuring driving rain and deluge rain resistance
- Underlay opening protector supplied to maintain the function of the underlay
- Integral 4mm insect screen
- Complies with current Building Regulations; BS5250 & BS5534, ICP2
Installation
- Cut underlay and fold out. Insert Underlay protector.
- Fix Versa tile in position to battens and remove backing sheet from flashing. Press flashing down to shape of tile ensuring seal to tile.
- Lay and fix tiles overlapping the universal tile on each side and compressing the foam filler.
- Continue tiling in the normal way.
Specifications
Code | IVTG5 |
Free Area | IVTG5—20,000mm² per vent |
Size | Universal |
Material | Manufactured from ABS & VO fire retardant material |
Colour | Terracotta, Brown, Grey, Red streak, Black, Blue/Black |
Airflow resistance when used as SVP (100mm pipe) | 54m³/hr 0.8Pa, 108m³/hr 2.6Pa, 216m³/hr 11.5Pa |
IVTG5 Airflow resistance with 150mm TT13 adaptor | 216m³/hr (60lt/sec) 19.5Pa |